Mcculloch Generator Fg5700ak Manual

View and Download McCulloch 7096-FG5733 user manual online. McCulloch Corporation Generator User Manual. 7096-FG5733 portable generator pdf manual download. Also for: Fg5700a, Fg5700ak. We have 1 McCulloch FG5700AK manual available for free PDF download: User Manual McCulloch FG5700AK User Manual (31 pages) McCulloch Corporation Generator User Manual.

  1. Mcculloch Generator Fg5700ak Owner's Manual
  2. Mcculloch Generator Fg5700ak Parts Diagram
  3. Mcculloch Generator Fg5700ak Parts List
  4. Mcculloch Generator Fg5700ak Manual
McCulloch FG5700AK 5,700 Watt 11 HP 338cc Portable Gas Powered Generator Description
The McCulloch 5,700-watt 11 HP portable power generator with wheel kit has a 5-gallon fuel tank for longer running time during blackouts. It's powered by an efficient 11 HP OHV engine with an easy pull recoil starter. This generator shuts off the ignition when dangerously low oil levels occur, and it's enclosed in a compact protective roll cage frame. A conveniently located on/off switch provides easy control of this generator, which provides a maximum of 5,700 watts. You'll also appreciate the large muffler that helps restrict noise from the generator, which is backed by a 1-year limited warranty.
Features
  • McCulloch 5,700-watt, 11-horsepower portable gas powered generator with easy pull recoil starter
  • Enclosed in protective compact roll cage
  • Low oil shutdown shuts off the ignition when dangerously low oil levels occur
  • Fold down handles for easy storage
  • Non-CARB Compliant/Not For Sale In California

This is a modern portable generator great for camping, fishing and out in the shop area, constructed with a permenant magnet alternator and an OHC gasoline combustion engine. The engine turns the rotor outside the stator to change the magnetic flux generated into AC electricity through an inverter to DC then transfer to AC output Fg5700ak
Mcculloch Generator Fg5700ak ManualThis review is from: McCulloch FG5700AK 5,700 Watt 11 HP 338cc Portable Gas Powered Generator
McCulloch generator 5700w, November 2, 2011 By AcePayday (USA)
I purchased this generator new for $630 from WalMart of all places and used it during a recent power outage that lasted 5 days. Once I installed the wheel kit and added oil (it comes without oil in it), I pulled on the starter rope twice and it fired right up. I ran it for five days straight, 24 hours a day, and it never once hiccuped. My unit has four 120VAC outlets for extension cords and one 240VAC 30amp outlet which is used to connect (via 10 gauge/4 wire cable with twist-lock connectors) to the plug mounted on the side of my house leading to the transfer switch wired to my main e-panel. This unit is a beast and much quieter than most generators. . It handled my deep well pump, refrigerator, oil furnace, TV, computer, microwave, toaster, can opener, e-skillet and lights in four rooms (about 3800W) at the same time without any difficulty and could have easily handled more. This unit saved our butts and made life almost normal during the power outage. I cannot speak highly enough about this unit and would recommend it without any hesitation to someone looking for emergency power backup!
Good little unit, February 26, 2010 By Derek Curlee (Yoakum, tx)
(REAL NAME)
I have had this unit for about 5 years. I have never had any mechanical problems or electrical issues with the generator. It does have one issue I am not pleased with. The recoil start cover is plastic. The eyelit that the coil rope runs through came loose on the rope guide and allowed the rope to cut through the cover. When this happened the rope jumped the spindle inside and I had to remove the cover and re-do the rope on the spring loaded spindle. Easy enough, but a majot pain non the less. If that cover piece would have been metal, I would have no problems with this unit.
McCulloch 11HP 5KW Generator FG5700AK, January 20, 2008 By Steve Hendrix (Ohio, USA)
Very nice little unit, though used very little thus far. Now that I have a generator, we'll probably never have another power outage <grin>. This unit has plenty of power for emergency household use. It definitely sees a LOAD when my big deep-well water pump kicks on, but handles it just fine.
The only con I've seen thus far is that it floods easily. Choke it for one pull only (maybe two if it's REALLY cold). Otherwise it starts easily on the first or second pull.

Mcculloch Generator Fg5700ak Owner's Manual

Mcculloch Generator Fg5700ak ManualNote that the picture Amazon is showing depicts a slightly more expensive model, with the side-mounted control panel. The one I received is the basic model, with the plugs right in the end of the generator, and no AC power switches. Just fine for my purposes, and the price was better than I've seen anywhere else.
Steve Hendrix

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MCCULLOCH FG5700AK. We hope that this MCCULLOCH FG5700AK user guide will be useful to you.

Lastmanuals help download the user guide MCCULLOCH FG5700AK.

Mcculloch Generator Fg5700ak Parts Diagram


Detailed instructions for use are in the User's Guide.

[. . . ] Refer to these serial numbers when ordering parts, and when making technical inquiry. SAFETY LABELS N These labels warn you of potential hazards that can cause serious injury. L I S Do not connect to a building's electrical system unless an isolation switch has been installed by a qualified electrician. Do not use a generator or electrical appliance in wet, conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet could result in electrocution. [. . . ] If any fuel is spilled, make sure the area is dry before starting the engine. We recommend unleaded gasoline because it produces fewer engine and spark plug deposits and extends exhaust system life. Occasionally you may hear light 'spark knock' or pinging' (metallic rapping noise) while operating under heavy loads. If spark knock or pinging occurs at a steady engine speed, under normal load, change brands of gasoline. G RECOIL STARTER To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. When the switch level move to ON position, fuel is allowed to flow from the fuel tank to the carburetor. 6-1B) N CHOKE LEVER (B) G The choke is used to provide an enriched fuel mixture when starting a cold eingine. 6-1C) I OIL ALERT SYSTEM S The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. H Before the oil level in the crankcase can fall below a safe limit, the oil alert system will automatically shut down the engine (the engine switch will remain in the ON position). Circuit Breaker The circuit breaker (A) will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle. If the circuit breaker is switched OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before switching the circuit breaker ON again. 6-2A) Ground Terminal The generator ground terminal (B) is connected to the frame of the generater, the metal non-current carrying parts of the generator, and the ground terminals of each receptacle. 6-2B) Connections to a Building's Electrical System Connections for standby power to a building's electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. Improper connections to a building's electrical system can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may electrocute utility company workers or others who contact the lines during a power outage. Improper connections to a building's electrical system can allow electrical current from the utility company to backfeed into the generator. When utility power is restored, the generator may explode, burn, or cause fires in the building's electrical system. In some areas, generators are required by law to be registered with local utility companies. Generator Ground Circuits McCulloch portable generators have a system ground that connects generator frame components to the ground terminals in the AC output receptacles. Local regulations, codes or laws may require that the ground system be connected to the AC neutral wire. If the generator is tested by a receptacle tester, it will not show the same ground circuit condition as for a home receptacle. [. . . ] Gasoline is extremely flammable and is explosive under certain conditions Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure. Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug. [. . . ]

Mcculloch Generator Fg5700ak Parts List

DISCLAIMER TO DOWNLOAD THE USER GUIDE MCCULLOCH FG5700AK

Mcculloch Generator Fg5700ak Manual

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on 'Download the user Manual' at the end of this Contract if you accept its terms, the downloading of the manual MCCULLOCH FG5700AK will begin.