To purchase PDF or hard copy Australian Standards, please email enquiries@standards.co.nz or call 0800 782 632 during business hours.
- Australian Standard As2870; Australian Standard As2870 Pdf Printer; Detailed information about joint Australian/New Zealand Standards can be found by visiting the Standards Web Shop at www.standards.com.au or Standards New Zealand web site at www.standards.co.nz and looking up the relevant Standard in. Design, construction and maintenance of residential slabs is regulated by Australian.
- Australian Standard’, which subscribing members receive, and which gives details of new publications, new editions and amendments, and of withdrawn Standards. Suggestions for improvements to Australian Standards, addressed to the head office of Standards Australia, are welcomed. Notification of any inaccuracy or ambiguity found in an.
Earthworks PDF 1MB 2007 Seminar Deep Foundations, Excavations and Retaining Walls in SA PDF 36.9MB Western Australia – Public Resources The Engineering of the Coastal Limestones of Western Australia. In March 2008, the Western Australian Chapter of the AGS held a seminar on The Engineering of the Coastal Limestones of Western Australia. Standards Australia is committed to maintaining a contemporary and relevant catalogue of Australian Standards® which add to the net benefit of the Australian community. The Aged Standards Review is one of the ways in which Standards Australia gives effect to that commitment.
- AS 2870-2011Residential slabs and footings
Sets out the criteria for the classification of a site and the design and construction of a footing system for a single dwelling house, townhouse or similar structure which may be detached or separated by a party wall or common wall, but not situated vertically above or below another dwelling, including buildings classified as Class 1 and Class 10a in the Building Code of Australia. The Standard may also be used for other forms of construction, including some light industrial, commercial and institutional buildings if they are similar to houses in size, loading and superstructure flexibility. The footing systems for which designs are given include slab on ground, stiffened rafts, waffle rafts, strip footings, pad footings and piled footings.
Supersedes AS 2870-1996 and AS 2870 Supp 1-1996 - AS 2896-2011Medical gas systems – Installation and testing of non-flammable medical gas pipeline systems
Sets out requirements for the safety aspects, construction, testing and certification, operation and maintenance of non-flammable medical gas pipeline systems used for patient care, therapeutic, diagnostic and for operating surgical tools. Non-flammable medical gas pipeline systems include suction pipeline systems. The Standard is intended to apply to suction systems for day care centres and clinical situations. It does not apply to suction systems for laboratories or hospital dental units.
Supersedes AS 2896-1998 - AS 4558-2011Decorative gas log and other fuel effect appliances
Specifies design, construction and marking requirements and test methods for decorative gas log, coal or other fuel effect fires with gas consumptions not exceeding 72 MJ/h. Two types of appliances are covered as defined in Clause 1.2. This Standard is limited to appliances that are designed primarily to have a decorative appearance.
Supersedes AS 4558-2000 (AG 108-2000) - AS 4773.2-2010Masonry in small buildings – Construction
Sets out construction practices for masonry in small buildings, such as houses, garages, small warehouses and the like.
Supersedes AS 3700-2001 (in part) - AS 4825-2011Tunnel fire safety
Provides a generic framework for establishing the fire safety systems that are required in new road, rail or bus tunnels to provide an acceptable level of safety in case of fire; provides guidance in the development of a fire safety strategy, the design and documentation of fire safety systems for tunnels.
New Amendments
- Amendment 1-2010 to AS 1860.2-2006Particleboard flooring – Installation
- Amendment 2-2011 to AS 2658-2008LP Gas – Portable and mobile appliances
- Amendment 1-2011 to AS 4553-2008Gas space heating appliances
- Amendment 1-2011 to AS 4555-2002(AG 105-2002)Domestic gas refrigerators
- Amendment 1-2011 to AS 4565-2004Radiant gas heaters for outdoor and non-residential indoor use
- Amendment 2-2010 to AS 5100.4-2004Bridge design – Bearing and deck joints
- Amendment 2-2010 to AS 5100.5-2004Bridge design – Concrete
- Amendment 2-2010 to AS 5100.6-2004Bridge design – Steel and composite construction
- Amendment 1-2011 to AS 6000-2009Organic and biodynamic products
Superseded and withdrawn Standards
- AS 2870-1996Residential slabs and footings – Construction
Superseded by AS 2870-2011 - AS 2870 Supp 1-1996Residential slabs and footings – Construction – Commentary (Supplement to AS 2870-1996)
Superseded by AS 2870-2011 - AS 2896-1998Medical gas systems – Installation and testing of non-flammable medical gas pipeline systems
Superseded by AS 2896-2011 - AS 3700-2001Masonry structures
Superseded (in part) by AS 4773.2-2010 - AS 4558-2000(AG 108-2000) Decorative gas log and other fuel effect appliances
Superseded by AS 4558-2011
AUSTRALIAN STANDARD AS2870 PDF
Australian Standard As2870 Pdf Downloadable
Design, construction and maintenance of residential slabs is regulated by Australian Standard AS – Residential slabs and footings. Australian Standard AS – Time for a change. With specific reference to the slab heave problem with waffle rafts. Frank Van der Woude, B.E., Ph.D. Bluestacks mac macro. AGS Vic. complying with the Australian Standard – AS referenced by the BCA. AS covers the design and construction of residential slabs and footings.
Author: | Shaktigis Nagar |
Country: | Ecuador |
Language: | English (Spanish) |
Genre: | History |
Published (Last): | 22 September 2006 |
Pages: | 407 |
PDF File Size: | 8.43 Mb |
ePub File Size: | 20.60 Mb |
ISBN: | 159-5-57379-444-7 |
Downloads: | 45240 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Yogami |
This Standard sets out the criteria for the classification of a site and the design and construction of a footing system for a single dwelling house, townhouse or similar structure which may be detached or separated by a party wall or common wall, but not situated ausralian above or below another dwelling, including buildings classified as Class 1 and Class 10a in the Building Code of Australia.
The Standard may also be used for other forms of construction, including some light industrial, commercial and institutional buildings if they are similar to houses in size, loading and superstructure flexibility. The footing systems for which designs are austrralian include slab on ground, stiffened rafts, waffle rafts, strip footings, pad footings and piled footings. This Australlan gives no advice on detailing of the connection of superstructures to the footing systems for wind loads or earthquake loads.
Standards Catalogue
For design purposes, the life of the structure is taken to be 50 years. Economical designs that avoid significant damage are practicable only if the soil moisture content of the foundation material under the footing or slab is stable or within reasonable standaard of stability over the design life of the house or structure. Residential slabs and footings. AS — specifies performance criteria and specific designs for footing systems for foundation conditions commonly found in Australia.
It also provides guidance on the design of footing systems, abiding by engineering principles. The standard sets out the criteria for the classification australiam a site, and the design and.
Australian Standard As2870 Pdf Download Adobe Reader
For all sites in particular sites with reactive soils drainage and soil moisture conditions around the building need to be managed to avoid abnormal moisture conditions, as outlined in Clause 1. AS — This is a free 7 page sample. It was approved on behalf of the Council of Standards Australia on 20 December This Standard was published on 17 January This is a free 7 page sample.
Could you please send me the 7 page sample.
PolyVoid – The Australian Standard has Changed
I have some trees that are too close to the house. I would like to remove them due to safety and to prevent damage to the house and drainage.
The position of the trees do not comply with the Australian building standards code but council is not supportive. They disregard our safety in favour of the tree protection. I would like to talk to some one from your department if possible. Download dmg el capitan.
Australian Standard As2870 Pdf Download Pdf
Regards David my mobile is January December Author Write something about yourself. No need to be fancy, just an overview. Powered by Create your own unique website with sandard templates. Regards David my mobile is Reply Leave a Reply.